Hygienic Air Handling Units
Viaclimate branded hygienic air handling units are designed in four different ways according to the fresh air supply of hygienic environments, exhaust of ambient air, heating, cooling, humidification, air filtration and heat recovery.
Hygienic air handling units need outdoor units to condition the air. Hygienic air handling units need outdoor units to condition the air.
Previous
Next
Viaclimate branded hygienic air handling units are of two types.
- 100% Fresh Air Conditioner Hygienic Air Handling Units
- 100% Fresh Air Conditioner Hygienic Air Handling Units
HygieneV Air Handling Units Eurovent Performance Values
- HygieneV catalog page 31
General features
Cell Structure
- Certified design in accordance with EN1886 standards
- Eurovent certified cell structure
- Eurovent certified cell structure
- Plastic (abs, pvc) materials conforming to ISO 846
- Thermal bridge-free design in VKSTB model
- Intracellular oval hygienic edges and corners
- Intracellular oval hygienic edges and corners
- Intracellular oval hygienic edges and corners
- Aluminum profiled carcass
- 60 mm double skin panel
- 110 kg/m3 rock wool insulation
- In the HygieneV model; outer panel sheet is 1mm painted galvanized, inner panel sheet is 1 mm stainless steel
- In the HygieneV model; outer panel sheet is 1mm painted galvanized, inner panel sheet is 1 mm stainless steel
- In the HygieneV model; outer panel sheet is 1mm painted galvanized, inner panel sheet is 1 mm stainless steel
Equipment Features
- Plug, Ec, moving parts
- AC or EC motors
- Water heat exchangers with copper tube, aluminum fins and steel collector
- Gas heat exchangers (DX) with copper tube, aluminum fins and copper collector
- Hydrophilic or epoxy coated heat exchangers
- Water heat exchangers with copper tube collector
- Water heat exchangers with copper tube collector
- Aluminum Plate, Water, Gas type heat recovery exchangers
- Epoxy coated heat recovery exchangers
- Epoxy coated heat recovery exchangers
- G2-M5 class panel filter
- M5-F9 class bag filter
- H10-H14 class compact or modular type filter
Standard Accessories
- Sight glass
- Lighting
- Door switch
- Stainless condensation pan
- negative pressure siphon
- Emergency stop
- Engine electrical junction box
- Standard warning and mounting labeling
- standard packaging
Optional Accessories
- Thermal magnetic circuit breaker
- Outdoor protection (roof) sheet
- Pop-up running gear protection guards
- Frequency inverter
- Automation field equipment
- Electrical Automation control panel
- Other..
Electrical Automation Control Points and Features
Analog Inputs
- Temperature sensor
- Humidity sensor
- Pressure sensor
- Frost protection temperature sensor
Analog Outputs
- Valve motor
- Motor frequency
- Damper motor
- Moisturizer
Digital Inputs
- Differential-pressure switch
- frost thermostat
- temperature thermostat
Digital Outputs
- Electric heater stage
- Fan start-stop
- Damper motor
- Valve motor
Checkpoints
- Room thermostat
- Return air
- Fresh air
- Touch screen
- ModBus (RS485)
- BACnet
Other Checkpoints
- Time programming
- Summer, winter and season transitions mode change
- VRF outdoor unit integration
- Feed water temperature
- Freecooling, freeheating
- Lighting
Alarms
- Engine thermal fault
- Belt broke
- Filter impurity
- Frost
- Electric heater malfunction
Safety Points
- Emergency stop
- Safety thermostat
- By-pass damper
- Rotor speed
- Heat recovery fluid velocity (aqueous type)
- Temperature thermostat
- Engine protection
- Door switch